Flexible Multi-Stack Super-Resolution of Clinical Brain MRI Using Hetero-Orientation Variational Encoding: Expert Reader Evaluation in a Nigerian Cohort
Abstract
MS-HVED enables flexible super-resolution of partially overlapping brain MRI stacks by fusing independently encoded multi-scale Gaussian posteriors with a field-of-view-aware Product-of-Gaussians and physics-informed domain randomisation, improving reconstruction, tissue segmentation, and external clinical generalisation.
High-resolution brain MRI is important for neuroradiological assessment, yet routine clinical protocols often rely on fast, anisotropic 2D acquisitions, particularly in resource-constrained settings. These acquisitions may differ in orientation, alignment and anatomical coverage, resulting in partially overlapping image stacks. Existing learning-based super-resolution methods typically rely on single, under-constrained inputs or fixed multi-stack configurations with idealised acquisition geometry. We introduce MS-HVED, a sequence-agnostic framework for flexible multi-stack brain MRI super-resolution. Available axial, coronal and sagittal stacks are independently encoded into multi-scale Gaussian posteriors and fused using a field-of-view-aware Product-of-Gaussians formulation that limits contributions from unsupported regions. Physics-informed domain randomisation simulates heterogeneous clinical acquisition conditions, including obliqueness, partial coverage and imaging artefacts. MS-HVED achieved competitive or superior reconstruction fidelity across synthetic benchmarks and improved downstream tissue segmentation relative to low-resolution inputs. To assess generalisation beyond the training cohorts, we performed external clinical validation on 30 routine brain MRI examinations from a Nigerian cohort, representing an under-represented population in medical imaging research. These examinations formed the largest component of a blinded reader study involving 44 real cases and seven expert neuroradiologists. In the Nigerian cohort, MS-HVED was preferred over the supervised baseline for overall image quality in 187 of 210 paired assessments. Across all clinical cohorts, MS-HVED achieved higher overall-quality scores with all available inputs (5.93 vs. 4.49, p<.001), with the preference persisting when axial or coronal inputs were omitted (p<.001). Code at github.com/cai4cai/ms-hved
Community
High-resolution brain MRI is important for neuroradiological assessment, yet routine clinical protocols often rely on fast, anisotropic 2D acquisitions, particularly in resource-constrained settings. These acquisitions may differ in orientation, alignment and anatomical coverage, resulting in partially overlapping image stacks. Existing learning-based super-resolution methods typically rely on single, under-constrained inputs or fixed multi-stack configurations with idealised acquisition geometry. We introduce MS-HVED, a sequence-agnostic framework for flexible multi-stack brain MRI super-resolution. Available axial, coronal and sagittal stacks are independently encoded into multi-scale Gaussian posteriors and fused using a field-of-view-aware Product-of-Gaussians formulation that limits contributions from unsupported regions. Physics-informed domain randomisation simulates heterogeneous clinical acquisition conditions, including obliqueness, partial coverage and imaging artefacts. MS-HVED achieved competitive or superior reconstruction fidelity across synthetic benchmarks and improved downstream tissue segmentation relative to low-resolution inputs. To assess generalisation beyond the training cohorts, we performed external clinical validation on 30 routine brain MRI examinations from a Nigerian cohort, representing an under-represented population in medical imaging research. These examinations formed the largest component of a blinded reader study involving 44 real cases and seven expert neuroradiologists. In the Nigerian cohort, MS-HVED was preferred over the supervised baseline for overall image quality in 187 of 210 paired assessments. Across all clinical cohorts, MS-HVED achieved higher overall-quality scores with all available inputs (5.93 vs. 4.49, p<.001), with the preference persisting when axial or coronal inputs were omitted (p<.001)
This is an automated message from the Librarian Bot. I found the following papers similar to this paper.
The following papers were recommended by the Semantic Scholar API
- Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian Prototypes (2026)
- Unified Multi-plane Autoregressive Diffusion for 3D Multi-contrast MRI Synthesis (2026)
- Uncertainty-Aware 3D Residual Wavelet Diffusion for Ultra Low-Field MRI Super-Resolution (2026)
- VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution (2026)
- MRI Super-Resolution with RCDM/WaveMix and Task-Aware Segmentation (2026)
- Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks (2026)
- GraphSVR: q-Space-Aware Graph-Based Slice-to-Volume Registration for Diffusion MRI (2026)
Please give a thumbs up to this comment if you found it helpful!
If you want recommendations for any Paper on Hugging Face checkout this Space
You can directly ask Librarian Bot for paper recommendations by tagging it in a comment: @librarian-bot recommend
Get this paper in your agent:
hf papers read 2611.21412 Don't have the latest CLI?
curl -LsSf https://hf.co/cli/install.sh | bash Models citing this paper 0
No model linking this paper
Datasets citing this paper 0
No dataset linking this paper
Spaces citing this paper 0
No Space linking this paper